Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8918369
![](http://i.b2b168.com/e/tag_pthy.gif)
- Product Categories
- Friendly Links
Information Name: | Supply Chang Hui, Hong Kong, level volume control, SWP-LCD-NH803 |
Published: | 2012-05-17 |
Validity: | 720 |
Specifications: | SWP-LCD-H803-21-23-HL |
Quantity: | 1000.00 |
Price Description: | |
Detailed Product Description: | SWP-LCD-NH (level volume control instrument) -------------------------------------------------- ------------------------------ SWP-LCD-NH Series level volume control instrument of the various shapes of the tank liquid level volume conversion measurement and control. First, the main features of 1, there is an extremely wide measurement range to display the entire five level measurement values ??and the entire six volume measurement value (0 - 99999 words). Using look-up table method for computing the change of control to achieve high-precision level of irregular tank volume. Second, the instrument shape and wiring diagram (The following is the basic wiring, special orders please refer to random wiring diagram) Model SWP-LCD-NH80 series of wiring diagram Meter Shape Instrument Size: 160 × 80 × 140mm Hole size: 152 × 76mm Weight: 400g Instrument size: 80 × 160 × 140mm Cut-out Dimensions: 76 x 152mm Weight: 400g SWP-LCD series level volume control instrument type spectrum table Ordering information SWP-LCD-N-□ □ □ □ □ - □ □ - □ □ - □ □ □ □ - □ - □ a new generation of large screen with backlight display instrument Instrument function H level volume control instrument HR with a record (level volume control instrument) Dimensions 8 160 × 80mm (horizontal type) 80 × 160mm (vertical) Control the role of 01 03 No control (or alarm) output With control (or alarm) output Means of communication - See "communication" Transmitter output □ See "Output Mode" Input type □ □ refer to "input type" First alarm mode - see "Alarm mode" Second alarm mode - see "Alarm mode" Third alarm mode "see" alarm mode " Feed output N P Power Output (optional) DC24V feed output Power supply W T DC24V power supply AC90 ~ 265V power supply (SMPS) AC220V power supply (linear power supply, can be omitted) Shape characteristics of S Vertical display instrument Horizontal display instrument (optional) ★ input type (factory default) Code input type measuring range code input type measuring range Description A 4 ~ 20 mA -9999 ~ 99999d D 0 ~ 5 V -9999 ~ 99999d this table lists the maximum range, users can modify the instrument two parameters determine the range in the range B 0 ~ 10 mA -9999 ~ 99999d R user-specific range C 1 ~ 5 V -9999 ~ 99999d ★ alarm mode Selection code for NHL Alarm mode bits control or alarm (optional)-position upper limit of control or the upper limit alarm bit lower limit of control or lower alarm ★ communication Selection code 02489 Communication communication RS-232 RS-422 RS-485 special specifications ★ output mode Selection code 02345 Output mode no output 4 ~ 20mA, 0 ~ 10mA, 1 ~ 5V 0 ~ 5V ★ Model example: ① SWP-LCD-NH801-02-AN LCD series, no control (or alarm) output level volume control device, the input type to 4 ~ 20mA, no communication, 4 ~ 20mA control output, alarm output, horizontal table. ② SWP-LCD-NH803-81-A-HLP LCD series with the control (or alarm) output level volume control device, the input type to 4 ~ 20mA, relay control output, with RS-485 communication, bring the lower limit of the relay alarm output with the output of DC24V feed, cross-table . Second, the special technical parameters PWM output control output mode, the SCR trigger output, solid-state relay output, the voltage / current output Set / display accuracy of +0.5% FS +1 digit max. Settings to match the displayed value, relative error Ratio range of 0.0% -100.0% (unit: 0.1%) Integral (reset) time of 0-9,999 s (unit: 1s) Time differential (ratio) 0-9,999 s (unit: 1s) Control cycle, 1-250s (Unit: 1s) Sampling cycle of 0.5s Third, the instrument shape and wiring diagram (The following is the basic wiring, special orders, please refer to random wiring diagram) Model SWP-LCD-NP series (horizontal) wiring diagram Instrument appearance Instrument Size: 160 × 80 × 140mm Hole size: 152 × 76mm Weight: 400g Instrument size: 80 × 160 × 140mm Cut-out Dimensions: 76 x 152mm Weight: 400g Four, paragraph 32 of the SWP-LCD-NP Series PID programmable process control instrument type spectrum table Ordering information SWP-LCD-N □ □ □ □ - □ □ □ - □ □ - □ □ - □ - □ - □ a new generation of large-screen with backlight LCD instrument Instrument function of P 32 PID for process control instrument Dimensions 8 160 x 80mm (horizontal), 80 x 160mm (vertical) Control of 05 PID regulator Means of communication - See "communication" Control outputs "refer to" control output mode Transmission output □ See transmitter output mode Input type □ □ refer to "input type" First alarm mode - see "Alarm output mode Second alarm mode "see" the alarm output mode Feed output P DC24V Power Output Power supply W T DC24V power supply AC90 ~ 265V power supply (SMPS) AC220V power supply (linear power supply, can be omitted) Shape characteristics of S Vertical display instrument Horizontal display instrument ★ Input Type Code input type measuring range code input type, measurement range code input type measuring range 01 B 400 ~ 1800 ℃ 09 Pt100.1 -99.9 ~ 199.9 ℃ 17 30 ~ 350Ω -1999 ~ 99999 d 02 S 0 ~ 1600 ℃ for 10 the Cu50 -50.0 ~ 150.0 ° C to 18 special specifications user specific 03 K, 0 ~ 1300 ℃ 11 Cu100 -50.0 to 150.0 ℃ 19 4 ~ 20 mA, square root -1 999 99999 d 04 E 0 ~ 1000 ℃ 12 4 ~ 20 mA, -1999 ~ 99999 d 20 0 ~ 10mA prescribing -1 999 ~ 99999 d 05 T--200 ~ 400 ℃ 13 0 ~ 10 mA, -1999 ~~ 99999 d 21 1 ~ 5 V square root -1 999 ~ 99999 d 06 J of 0 ~ 1200 ℃ 14 1 ~ 5 V -1999 ~ 99999 d 22 0 ~ 5 V square root -1 999 ~ 99999 d 07 Wre 0 ~ 2300 ℃ 15 0 ~ 5 V--1999 ~ 99999 23 full switch input in the table below -200 ~ 650 ℃ 16 ~ 20 mA, -1999 ~ 99999 d 24 of 08 Pt100 frequency input 0 ~ 10KHz ★ full-switch input just set the instrument two parameters, you can switch to input a variety of sub-degree No., enter the sub-degree numbers are as follows: Code input type code input type code input type code input type code input type 01 B, 05 T-09 Pt100.1 14 1 ~ 5 V 21 1 ~ 5 V prescription 02 S-06 J of 10 Cu50 15 0 ~ 5 V 22 0 ~ 5 V-prescribing 03 K, 07 WRe 12 4 ~ 20 mA, 19 4 ~ 20 mA, prescribing 04 E-08 Pt100 13 0 ~ 10 mA, 0 ~ 10mA prescribing ★ alarm output mode Selection code NHLGAD. Output mode alarm (optional) LBA alarm alarm alarm deviation outside the alarm deviation of the upper alarm limit ★ transmitter output mode Selection code 012 345 Output mode output relay 4 to 20mA, 0 ~ 10mA, 1 ~ 5V, 0 ~ 5V ★ communication Selection code 02489 Communication communication RS-232 RS-422 RS-485 special specifications ★ control output mode Order code 0123456789 Output mode output relay 4 ~ 20mA 0 to 10mA 1 ~ 5V 0 ~ 5V SCR output SSR outputs special specifications SOT output SCR - SCR zero trigger pulse output, SSR - solid-state relay control output SOT - triac output ★ Model example: ① SWP-LCD-NP805-21-09-HL-PWS Communication RS-232 output for the relay output input type Pt100.1, the first alarm for the upper limit alarm, second alarm for the lower limit alarm, DC24V Power Output, DC24V power supply, the vertical table. ② SWP-LCD-NP805-81-08-LH-PT Communication RS-485 output for relay output, the input type Pt100, the first alarm for the lower limit alarm, second alarm limit alarm DC24V feed output, AC90 ~ 265V power supply (SMPS), cross-table . Wholesale Description |
Admin>>>
You are the 11718 visitor
Copyright © GuangDong ICP No. 10089450, Fujian on the Run Instrument Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 11718 visitor
Copyright © GuangDong ICP No. 10089450, Fujian on the Run Instrument Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility